We would like to inform you that the Clinical Trial Registry page will discontinue the function of updating trial information directly on this platform. However, you will still be able to view the existing registration details. For any updates to trial information, you can use the China Clinical Trial Registry (ChiCTR) directly at https://www.chictr.org.cn. This change will be fully implemented by 2024-Aug-05. Thank you for your attention.
CUHK_CCT00407
2014-04-17
Prospective
Nil
Department of Ophthalmology and Visual Sciences, the Chinese University of Hong Kong
Department of Ophthalmology and Visual Sciences, the Chinese University of Hong Kong
Nil
Ms. Jennifer Tsoi
Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, 3/F, Hong Kong Eye Hospital, 147K Argyle Street, Kowloon
39435869
jennifertsoi@cuhk.edu.hk
The Chinese University of Hong Kong
Prof. LEUNG Kai Shun Christopher
Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, 3/F, Hong Kong Eye Hospital, 147K Argyle Street, Kowloon
3943 5846
cksleung@cuhk.edu.hk
The Chinese University of Hong Kong
A Randomized Controlled Trial Comparing the Efficacy and Safety between Pattern Laser Trabeculoplasty and Selective Laser Trabeculoplasty
A Randomized Controlled Trial Comparing the Efficacy and Safety between Pattern Laser Trabeculoplasty and Selective Laser Trabeculoplasty
模式化激光小梁成形術與選擇性激光小梁成形術療效及安全性的隨機對照試驗
PLT vs SLT
Hong Kong
Yes
2013-07-18
Glaucoma
Procedure
Patterned Laser Trabeculoplasty (PLT)
Selective Laser Trabeculoplasty (SLT)
The total duration of laser treatment is approximately 10 minutes.
Regarding selective laser trabeculoplasty (SLT), a drop of Brimonidine will be instilled into the eye to be treated 15 minutes prior to the procedure. Topical anaesthesia will be administered and the Latina SLT lens and coupling fluid will be used for the procedure. The slit-lamp attached to the laser will be focused on the full height of the trabecular meshwork. The laser power will be set to 0.6mJ and increased in 0.1mJ steps until small champagne –like bubbles appear from the treated area of the trabecular meshwork.Approximately 50-60 non-overlapping shots will be placed onto at least 180 degrees of the trabecular meshwork that is visible and without PAS. More non-overlapping shots can be placed if sufficient extent of the trabeculum is visible.A second laser treatment targeting the same previously treated area of the meshwork can be done at the 1 or 4 week follow up visit if the IOP returns to pretreatment levels.
Patterned laser trabeculoplasty has a therapeutic wavelength of 532nm and a spot size of 100 µm. Power is titrated using a single spot to achieve light trabecular meshwork blanching with 10-ms laser pulses in the inferior segment of the eye. After titration the power is maintained but the pulse duration is reduced to 5ms, and a predetermined pattern of laser spots are used. Laser beams are directed on the trabecular meshwork for 180-360 degrees. The total duration of laser treatment is approximately 10 minutes.
-A diagnosis of POAG or OHT
-Older than 18 years of age
-Able to give informed consent
-Significant cataract rendering visual field testing or optic disc imaging not technically possible
-Previous SLT or ALT
-Previous glaucoma surgery
-Participation in another therapeutic drug study within the last 30 days
-Severe health problems precluding follow-up such as end-stage heart disease, kidney disease, respiratory disease, or cancer.
-Patients using systemic steroids
Older than 18 years of age
999
Both Male and Female
Interventional
Randomized
Active
Single-blind
Parallel
2014-05-01
132
Not Yet Recruiting
Intraocular pressure will be measured with Goldmann applanation tonometry at baseline, 1 week, 1 month, 3 months and 6 months, 9 months and 1 year after PLT or SLT treatment.
The density of cataract will be assessed with the Lens Opacity Classification System III (LOCS III) with standard color photographs as the reference for grading of lens opacity. Progression in lens opacity was defined as an increase in LOCS III grade by 2 or more units in any lens region.
2019-07-30
ChiCTR-TRC-14004521
2014-04-17
Yes
Nil
|
|
|
|
|
---|---|---|---|---|